Whole-house filter GPM calculator
Add up your fixtures to get the simultaneous peak flow rate your filter must handle, then match the housing.
The guide
Flow first, media second
A whole-house filter sits on the main line, so it sees your simultaneous peak demand. If the filter's rated flow is lower than your peak, pressure drops when a shower, washer and sink run together. GPM is the first number to match.
Source: eCFR 10 CFR 430.32: federal flow limits for faucets and showerheads
Standard US values used
| Fixture | GPM | Basis | Source |
|---|---|---|---|
| Kitchen faucet | 2.2 | federal maximum | 10 CFR 430.32 - federal max 2.2 GPM at 60 psi for faucets |
| Bathroom sink | 1.5 | WaterSense maximum | EPA WaterSense bathroom faucets - max 1.5 GPM |
| Shower | 2.5 | federal maximum | 10 CFR 430.32 - federal max 2.5 GPM at 80 psi for showerheads (WaterSense-labeled heads are 2.0 GPM or less) |
| Bathtub filler | 4 | assumed | Common plumbing design value for tub fill; verify against local code and your tub spout |
| Toilet (tank refill) | 3 | assumed | WaterSense toilets use 1.28 gallons per flush at most; refill rate of ~3 GPM is a common design assumption |
| Dishwasher | 2 | assumed | Common plumbing design value for appliance fill |
| Clothes washer | 3 | assumed | Common plumbing design value for appliance fill |
| Outdoor hose bib | 5 | assumed | Common plumbing design value for a 1/2 inch hose bib at typical pressure. Most homes bypass outdoor taps around the filter. |
Matching housing to flow
| Peak GPM | Sediment housing | Carbon / chlorine stage |
|---|---|---|
| up to 4 | 4.5" x 10" big-body housing | 4.5" x 10" or 4.5" x 20" carbon block |
| 4 to 7 | 4.5" x 10" big-body housing | 4.5" x 20" carbon block or 1.0 cu ft tank |
| 7 to 12 | 4.5" x 10"–20" big-body housing | 1.5 cu ft carbon tank (or parallel 4.5" x 20") |
| 12 to 16 | 4.5" x 20"–parallel housings | 2.0 cu ft carbon media tank |
| over 16–20 | Tank or parallel housings by installer | 2.5+ cu ft or parallel tanks by installer |
Typical manufacturer rating ranges (carbon needs contact time, so cartridge carbon blocks rate much lower than sediment cartridges); always check rated service flow at your pressure.
Frequently asked questions
How many GPM does a typical house need?
A two-bathroom home has ~21 GPM of total connected fixtures, but realistic simultaneous peak demand is typically ~10 to 13 GPM (~60% concurrency), and your supply line or well pump sets the real ceiling.
What happens if the filter is rated too low?
You get pressure drop at the taps, faster cartridge wear, and in carbon media less contact time. Carbon blocks flow much slower than sediment cartridges (a 4.5" x 20" carbon block is typically rated ~4–7 GPM vs ~15 GPM for sediment).
Where do the flow rates come from?
Faucets and showerheads use federal maximums and EPA WaterSense values; appliance and tub values are common design assumptions labeled as such in the table.
Does the filter fix hard water?
No; use the softener sizer for hardness.