Whole-house filter GPM calculator

Add up your fixtures to get the simultaneous peak flow rate your filter must handle, then match the housing.

Size a whole-house filter

Water source
Sets the default number of sinks, showers and toilets below. Edit any of them.
Fixtures and appliances

Loading fixture flow rates…

What are you trying to address? (pick any) Lead and PFAS can only be confirmed by a lab test. Find a certified lab first.
Optional: Home Water Score inputs
Planning estimates only. Verify your numbers with a certified lab test, and have any installation done by a licensed plumber. Results are estimates, not engineering, plumbing, medical, or legal advice, and no health claims are made. See the terms.

The guide

Flow first, media second

A whole-house filter sits on the main line, so it sees your simultaneous peak demand. If the filter's rated flow is lower than your peak, pressure drops when a shower, washer and sink run together. GPM is the first number to match.

Source: eCFR 10 CFR 430.32: federal flow limits for faucets and showerheads

Standard US values used

Matching housing to flow

Peak GPMSediment housingCarbon / chlorine stage
up to 44.5" x 10" big-body housing4.5" x 10" or 4.5" x 20" carbon block
4 to 74.5" x 10" big-body housing4.5" x 20" carbon block or 1.0 cu ft tank
7 to 124.5" x 10"–20" big-body housing1.5 cu ft carbon tank (or parallel 4.5" x 20")
12 to 164.5" x 20"–parallel housings2.0 cu ft carbon media tank
over 16–20Tank or parallel housings by installer2.5+ cu ft or parallel tanks by installer

Typical manufacturer rating ranges (carbon needs contact time, so cartridge carbon blocks rate much lower than sediment cartridges); always check rated service flow at your pressure.

Frequently asked questions

How many GPM does a typical house need?

A two-bathroom home has ~21 GPM of total connected fixtures, but realistic simultaneous peak demand is typically ~10 to 13 GPM (~60% concurrency), and your supply line or well pump sets the real ceiling.

What happens if the filter is rated too low?

You get pressure drop at the taps, faster cartridge wear, and in carbon media less contact time. Carbon blocks flow much slower than sediment cartridges (a 4.5" x 20" carbon block is typically rated ~4–7 GPM vs ~15 GPM for sediment).

Where do the flow rates come from?

Faucets and showerheads use federal maximums and EPA WaterSense values; appliance and tub values are common design assumptions labeled as such in the table.

Does the filter fix hard water?

No; use the softener sizer for hardness.

Sources